| Model |
|
|
|
|
|
|
|
|
|
Model
|
| Price |
$609.00
|
$355.50
|
$219.99
|
$199.00 or $224.00
|
$158.00
|
$77.00
|
$58.99 or $63.99
|
$49.99
|
$41.50
|
Price
|
| Brand |
Freevolve
|
Phonetics d/b/a Sensaphone
|
DIYControls.com
|
Bay Controls
|
Control Products
|
Control Products
|
Reliance Controls
|
Control Products
|
Reliance Controls
|
Brand
|
| Monitors for... |
Both Low and High Temp, plus Power Outages and more with optional sensors.
|
Both Low and High Temp, plus Power Outages and more with optional sensors.
|
Both Low and High Temp, plus Power Outages and more with optional sensors.
|
Both Low and High Temp, plus more with optional sensors.
|
EITHER Low or High Temp (select one mode), plus Power Outages
|
EITHER Low or High Temp (select one mode) plus Power Outages
plus Flood
|
Low Temp and Power Outages
plus Flood (THP201 only)
|
EITHER Low or High Temp (select one mode)
|
Low Temp
|
Monitors for...
|
| Alarm Condition Delay |
None for temp, 30 mins. for power
|
Adjustable
|
No
|
No
|
Select 0 or 45 mins
|
Power-out only: Select 15 or 60 minutes
|
Select 5 or 30 minutes
|
No
|
No
|
Alarm Condition Delay
|
| Temperature Setpoint |
Fixed 40 F/90 F
|
Adjustable
|
Adjustable
|
Adjustable
|
Adjustable
|
Fixed 45 F or 85 F
|
Fixed 45 F
|
Fixed 45 F
or 85 F
|
Fixed 42 F
|
Temperature Setpoint
|
| Recites actual temp on phone call |
Yes
|
Yes
|
No
|
No voice (alerts sent via email/SMS)
|
Yes
|
No
|
No
|
No
|
No
|
Recites actual temp on phone call
|
| Calls how many phone numbers? |
5
|
4
|
4
|
No voice (unlimited email/SMS)
|
3
|
3
|
3
|
1
|
5
|
Calls how many phone numbers?
|
| Number of call retries |
Infinite
|
Select 1 thru 255
|
Select 1 thru 15
|
n/a
|
Infinite
|
Infinite
|
Infinite
|
Infinite
|
Select 1 thru 5
|
Number of call retries
|
| Intercall delay |
20 mins
|
Select 10 secs thru 60 mins
|
Select 30 or 60 secs
|
Choices between 10 mins and 2 hours
|
Select 15 or 120 mins
|
Select 15 mins or 60 mins
|
15 mins between rounds
|
Select 15 or 120 mins
|
None
|
Intercall delay
|
| Stops calling if temp restores |
Yes
|
No
|
No
|
Yes
|
No
|
No
|
Yes
|
Yes
|
No
|
Stops calling if temp restores
|
| Alarm calls re-initiate after acknowledgement if condition still exists |
No
|
No
|
No
|
No
|
No
|
No
|
60 minutes after acknowledgement
|
No
|
N/A (no acknowledgement feature)
|
Alarm calls re-initiate after acknowledgement if condition still exists
|
| Call-in to hear exact temperature |
Yes
|
Yes
|
No
|
No voice, temp avail. on web/smartphone
|
Yes
|
No
|
No
|
No
|
No
|
Call-in to hear exact temperature
|
| Call-in to enable/disable monitoring |
No
|
Yes
|
Yes
|
Login via web
|
No
|
No
|
No, but can disable when it calls you. (Disable requires physical reset in order to re-enable)
|
No
|
No
|
Call-in to enable/disable monitoring
|
| Remote programming? |
Yes: Enable/Disable, Change phone numbers, Activate Outputs, Status Report
|
Yes: Enable/Disable, Change temp setpoints, Change phone numbers, Record voice msgs, Activate Output, Listen-in, Status Report
|
Yes: Enable/Disable, Change phone numbers, Activate Output, Listen-in
|
Yes, via web
|
Yes: Change temp setpoints, Change phone numbers, Status Report
|
No
|
No
|
No
|
No
|
Remote programming?
|
| Answering Machine Support |
Yes
|
Yes
|
Yes
|
n/a
|
Yes
|
Yes
|
N/A (no call-in capability)
|
Yes
|
N/A (no call-in capability)
|
Answering Machine Support
|
| VOIP Compatible |
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
VOIP Compatible
|
| Power Outage Notification |
Yes
|
Yes
|
Yes
|
With optional sensor
|
Yes
|
Yes
|
Yes
|
No
|
No
|
Power Outage Notification
|
| Power Out Reaction Time |
30 mins
|
Adjustable
|
Adjustable
|
Instant
|
Select between 0 and 120 minutes
|
Select 15 or 60 mins
|
Select 5 or 30 mins
|
N/A
|
N/A
|
Power Out Reaction Time
|
| Additional conditions monitored |
Batteries, Power. Optional add-ons for alerts/control of: Water/flood, garage doors, multiple thermostats, HVAC
|
High sound level, power, plus many optional add-on sensors are available
|
Batteries, Power, plus many optional add-on sensors are available
|
HVAC usage, offline/device failure. Optional add-on sensors for wireless intrusion or wired flood, smoke, power, and more.
|
Battery, Power
|
Flood, Power, Battery
|
Flood, Power
|
None
|
None
|
Additional conditions monitored
|
| Remote Control Thermostat Compatible |
Yes, Adjustable
|
Yes, Toggle (setback)
|
Yes, Toggle (setback)
|
Yes, Adjustable
|
No
|
No
|
No
|
No
|
No
|
Remote Control Thermostat Compatible
|
| Battery Backup |
Yes, Rechargeable, Included
|
Alkaline only
(6) C-Cells
Not included
|
Rechargeable
(6) AA NIMH
Included
|
No (suggested use of external UPS)
|
Alkaline or Lithium
(1) 9VDC
(Lithium Recomm.)
Not included
|
Alkaline only
(2) AA
Not Included
|
Alkaline only
(1) 9VDC
Included
|
Alkaline or Lithium
(1) 9VDC*
(Lithium Recomm.)
Not included
*This unit is purely battery powered (no AC adapter)
|
Alkaline only
(1) 9VDC
Not included
|
Battery Backup
|
| What you will hear when it calls you |
"housEvolve report... two alerts... freeze alert... power failure alert... end report. Current temperature 39 degrees." Also recites HVAC status and menu prompts.
|
Your own recorded voice label plus the current temperature, AC and battery status, status of optional added sensors, and microphone.
|
Your own recorded voice label, plus option to enter operations menu for arm/disarm, bypass, output activation, and microphone.
|
No voice. Email/SMS will contain temperature and/or alert condition.
|
Your own recorded voice label, followed by factory-recorded alarm messages telling you specifically what alarm conditions are or have recently occurred.
|
This is your HomeSitter Alarm calling. You have a [temperature, power, water, battery] emergency at your monitored location.
|
"Warning - Alarm condition. One beep is for temperature, two power, three accessory (THP201 only). A long beep is for multiple alarms. Press # to acknowledge or press * and then 0 to disable."
|
“This is your temperature monitoring system. There is a temperature alarm at your monitored location.Please check conditions at your monitored location."
|
An alarm tone.
|
What you will hear when it calls you
|
| How to acknowledge |
Press *#* when prompted
|
Enter 555 or call unit back
|
Press 2 and enter user code followed by pound (#)
|
n/a
|
Enter security code or call unit back and enter code.
|
Press 1# during alarm call or call unit back
|
Press and hold # key or press *0 to disable
|
Call unit back
|
Cannot acknowledge
|
How to acknowledge
|