| Model |
|
|
|
|
|
|
|
|
|
|
Model
|
| Brand |
|
|
|
|
|
Various Manufacturers
|
|
|
|
|
Brand
|
| Monitors for... |
Both Low and High Temp, plus Power Outages and more with optional sensors.
|
Both Low and High Temp, plus Power Outages and more with optional sensors.
|
EITHER Low or High Temp, plus Power Outages and additional wireless temp sensors (up to 10 total).
|
Both Low and High Temp, plus Power Outages and more conditions with optional sensors.
|
Both Low and High Temp, plus Power Outages and more with optional sensors.
|
Both Low and High Temp, plus some models monitor more conditions with optional sensors.
|
EITHER Low or High Temp (select one mode), plus Power Outages
|
Both Low and High Temp, including Outdoor
|
EITHER Low or High Temp (select one mode) plus Power Outages
plus Flood
|
EITHER Low or High Temp (select
one mode)
|
Monitors for...
|
| Alarm Condition Delay |
None for temp, 30 mins. for power
|
Adjustable
|
Select 0 or 60 minutes
|
Select 0 or 45 mins
|
No
|
See product info
|
Select 0 or 45 mins
|
Select 0, 30, 45, 60 or 75 seconds
|
Power-out only: Select 15 or 60 minutes
|
No
|
Alarm Condition Delay
|
| Temperature Setpoint |
Fixed 40 F/90 F
|
Adjustable
|
Adjustable (but all additional sensors use same temp setpoint)
|
Adjustable
|
Adjustable
|
Adjustable
|
Adjustable
|
Adjustable
|
Fixed 45 F or 85 F
|
Fixed
45 F
or 85 F
|
Temperature Setpoint
|
| Recites actual temp on phone call |
Yes
|
Yes
|
Yes
|
Yes
|
No
|
No voice (alerts sent via email/SMS)
|
Yes
|
No
|
No
|
No
|
Recites actual temp on phone call
|
| What you will hear when it calls you |
"housEvolve report... two alerts... freeze alert... power failure alert... end report. Current temperature 39 degrees." Also recites HVAC status and menu prompts.
|
Your own recorded voice label plus the current temperature, AC and battery status, status of optional added sensors, and microphone.
|
Your own recorded voice label, then "The following alarms currently exist or have occurred recently at location ####." Unit will recite alarms & which sensors have them. Then it offers options to repeat or acknowledge.
|
Your own recorded voice label, followed by factory-recorded alarm messages telling you specifically what alarm conditions are or have recently occurred.
|
Your own recorded voice label, plus option to enter operations menu for arm/disarm, bypass, output activation, and microphone.
|
No voice. Email/SMS will contain temperature and/or alert condition.
|
Your own recorded voice label, followed by factory-recorded alarm messages telling you specifically what alarm conditions are or have recently occurred.
|
Your own recorded voice label
|
"This is your HomeSitter Alarm calling. You have a [temperature, power, water, battery] emergency at your monitored location."
|
"Hello, This is
your Freeze Alarm calling. The following alarm conditions exist or have
occurred recently at your monitored location" followed by the specific
alarm message "There is a temperature alarm" or "There is a battery
alarm."
|
What you will hear when it calls you
|
| Calls how many phone numbers? |
5
|
4
|
3
|
3
|
4
|
No voice (unlimited email/SMS)
|
3
|
9
|
3
|
1
|
Calls how many phone numbers?
|
| Number of call retries |
Infinite
|
Select 1 thru 255
|
Infinite
|
Infinite
|
Select 1 thru 15
|
N/A
|
Infinite
|
Select 1 thru 9
|
Infinite
|
Infinite
|
Number of call retries
|
| Intercall delay |
20 mins
|
Select 10 secs thru 60 mins
|
15 mins between rounds
|
Select 15 or 120 mins
|
Select 30 or 60 secs
|
See product info
|
Select 15 or 120 mins
|
No
|
Select 15 mins or 60 mins
|
Select 15 or 120
mins
|
Intercall delay
|
| Stops calling if temp restores |
Yes
|
No
|
No
|
No
|
No
|
See product info
|
No
|
No
|
No
|
No
|
Stops calling if temp restores
|
| Alarm calls re-initiate after acknowledgement if condition still exists |
No
|
No
|
No
|
No
|
No
|
See product info
|
No
|
No
|
No
|
No
|
Alarm calls re-initiate after acknowledgement if condition still exists
|
| Call-in to hear exact temperature |
Yes
|
Yes
|
Yes
|
Yes
|
No
|
No voice, but accessible via web/smartphone
|
Yes
|
No
|
No
|
No
|
Call-in to hear exact temperature
|
| Call-in to enable/disable monitoring |
No
|
Yes
|
No
|
No
|
Yes
|
Login via web
|
No
|
No
|
No
|
No
|
Call-in to enable/disable monitoring
|
| Remote programming? |
Yes: Enable/Disable, Change phone numbers, Activate Outputs, Status Report
|
Yes: Enable/Disable, Change temp setpoints, Change phone numbers, Record voice msgs, Activate Output, Listen-in, Status Report
|
Yes: Change temp setpoints, Change phone numbers, Change security code, Change # of rings, Change power delay, Status Report
|
Yes: Review or change telephone numbers, temp setpoints, security code, messages, auxiliary alarm setting
|
Yes: Enable/Disable, Change phone numbers, Activate Output, Listen-in
|
Yes, via web
|
Yes: Change temp setpoints, Change phone numbers, Status Report
|
No
|
No
|
No
|
Remote programming?
|
| Answering Machine Support |
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
N/A
|
Yes
|
No
|
Yes
|
Yes
|
Answering Machine Support
|
| VOIP Compatible |
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
Yes if VOIP system has own battery backup
|
SEE NOTE ON PRODUCT PAGE
|
Yes if VOIP system has own battery backup
|
VOIP Compatible
|
| Power Outage Notification |
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
With optional sensor (some models)
|
Yes
|
No
|
Yes
|
No
|
Power Outage Notification
|
| Power Out Reaction Time |
30 mins
|
Adjustable
|
Adjustable
|
Select between 1 and 120 minutes
|
Adjustable
|
See product info
|
Select between 0 and 120 minutes
|
N/A
|
Select 15 or 60 mins
|
N/A
|
Power Out Reaction Time
|
| Additional conditions monitored |
Batteries, Power. Optional add-ons for alerts/control of: Water/flood, garage doors, multiple thermostats, HVAC
|
High sound level, power, plus many optional add-on sensors are available
|
Batteries, Power, plus optional extra temp sensors
|
Battery, Power, plus optional add-on sensors for flood, intrusion
|
Batteries, Power, plus many optional add-on sensors are available
|
HVAC usage, offline/device failure. Optional add-on sensors for wireless intrusion or wired flood, smoke, power, and more (some models)
|
Battery, Power
|
Many optional add-on sensors are available
|
Flood, Power, Battery
|
Batteries
|
Additional conditions monitored
|
| Remote Control Thermostat Compatible |
Yes, Adjustable
|
Yes, Toggle (setback)
|
No
|
No
|
Yes, Toggle (setback)
|
Yes, Adjustable
|
No
|
No
|
No
|
No
|
Remote Control Thermostat Compatible
|
| Battery Backup |
Yes, Rechargeable, Included
|
Alkaline only
(6) C-Cells
Not included
|
Base station uses 9V battery for back-up. Not included. Sensors are powered by 2 AA batteries. Not included.
|
Alkaline or Lithium
(1) 9VDC
(Lithium Recomm.)
Not included
|
Rechargeable
(6) AA NIMH
Included
|
No (suggested use of external UPS)
|
Alkaline or Lithium
(1) 9VDC
(Lithium Recomm.)
Not included
|
Alkaline only
(1) 9VDC
Included
|
Alkaline only
(2) AA
Not Included
|
(2) AA Batteries
Not included
|
Battery Backup
|
| How to acknowledge |
Press *#* when prompted
|
Enter 555 or call unit back
|
Enter security code or call unit back and enter code.
|
Enter security code or call unit back and enter code.
|
Press 2 and enter user code followed by pound (#)
|
N/A
|
Enter security code or call unit back and enter code.
|
Press # during alarm call
|
Press 1# during alarm call or call unit back
|
Press 1# during
alarm call or call unit back
|
How to acknowledge
|